高速増殖炉ヘリカル伝熱管探傷プローブの振動によるセンサノイズとその対策: 第3報, 数値シミュレーションによるパラメータスタディ

井上 卓見, 前原 猛, 末岡 淳男, 中野 寛, 金元 啓幸, 村上 敬宜

研究成果: Contribution to journalArticle査読

抄録

An eddy current testing (ECT) probe is used for a diagnosis of a helical heating tube installed in a fast breeder reactor, and a vibration of ECT probe makes the diagnosis difficult. In our previous report, we proposed an analytical model of the ECT probe incorporating with a frictional force and confirmed that the vibration was caused by Coulomb friction. In this paper, it is shown that numerical simulations utilizing the analytical model agree with various experimental results of the vibration of ECT probe, so that the reliability of the analytical model and the numerical simulation is increased. It follows that a preceding estimation of the vibration is available by the numerical simulation. Based on a behavior of the entire probe, which is obtained by the numerical simulation, we discuss a countermeasure to suppress the probe vibration. The validity of countermeasure is demonstrated through the numerical simulations.
寄稿の翻訳タイトルSensor Noise Caused by Vibrations of Flaw Detection Probe Generated in Helical Heating Tubes in a Fast Breeder Reactor and Its Countermeasures: 3rd Report, Parameter Study by Numerical Simulations
本文言語Japanese
ページ(範囲)3185-3192
ページ数8
ジャーナルNippon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C
72
722
出版ステータス出版済み - 10 25 2006

フィンガープリント 「高速増殖炉ヘリカル伝熱管探傷プローブの振動によるセンサノイズとその対策: 第3報, 数値シミュレーションによるパラメータスタディ」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。