The dual energy imaging technique was applied to intra-oral radiography to allow accurate measurement of the bone mineral content without hindrance from the soft tissues. A pair of intra-oral films separated with an inter-film filter was used in a conventional radiographic system, and an aluminum equivalent image was decomposed from these images by computerized image processing. The optimum thickness of copper or tin inter-film filters for use in the single exposure dual energy imaging was investigated by computer simulation and experimental studies. In addition, the accuracy of bone mineral content measurement by this method was also investigated.

元の言語英語
ページ(範囲)31-40
ページ数10
ジャーナルOral Radiology
7
発行部数2
DOI
出版物ステータス出版済み - 12 1 1991
外部発表Yes

Fingerprint

Radiography
Bone Density
Tin
Aluminum
Computer Simulation
Copper

All Science Journal Classification (ASJC) codes

  • Radiology Nuclear Medicine and imaging

これを引用

Single exposure dual energy imaging in intra-oral radiography. / Ohki, Masafumi.

:: Oral Radiology, 巻 7, 番号 2, 01.12.1991, p. 31-40.

研究成果: ジャーナルへの寄稿記事

Ohki, Masafumi. / Single exposure dual energy imaging in intra-oral radiography. :: Oral Radiology. 1991 ; 巻 7, 番号 2. pp. 31-40.
@article{c826cf5c0b1a4e7f9b9e4b512291642e,
title = "Single exposure dual energy imaging in intra-oral radiography",
abstract = "The dual energy imaging technique was applied to intra-oral radiography to allow accurate measurement of the bone mineral content without hindrance from the soft tissues. A pair of intra-oral films separated with an inter-film filter was used in a conventional radiographic system, and an aluminum equivalent image was decomposed from these images by computerized image processing. The optimum thickness of copper or tin inter-film filters for use in the single exposure dual energy imaging was investigated by computer simulation and experimental studies. In addition, the accuracy of bone mineral content measurement by this method was also investigated.",
author = "Masafumi Ohki",
year = "1991",
month = "12",
day = "1",
doi = "10.1007/BF02347874",
language = "English",
volume = "7",
pages = "31--40",
journal = "Oral Radiology",
issn = "0911-6028",
publisher = "Springer Japan",
number = "2",

}

TY - JOUR

T1 - Single exposure dual energy imaging in intra-oral radiography

AU - Ohki, Masafumi

PY - 1991/12/1

Y1 - 1991/12/1

N2 - The dual energy imaging technique was applied to intra-oral radiography to allow accurate measurement of the bone mineral content without hindrance from the soft tissues. A pair of intra-oral films separated with an inter-film filter was used in a conventional radiographic system, and an aluminum equivalent image was decomposed from these images by computerized image processing. The optimum thickness of copper or tin inter-film filters for use in the single exposure dual energy imaging was investigated by computer simulation and experimental studies. In addition, the accuracy of bone mineral content measurement by this method was also investigated.

AB - The dual energy imaging technique was applied to intra-oral radiography to allow accurate measurement of the bone mineral content without hindrance from the soft tissues. A pair of intra-oral films separated with an inter-film filter was used in a conventional radiographic system, and an aluminum equivalent image was decomposed from these images by computerized image processing. The optimum thickness of copper or tin inter-film filters for use in the single exposure dual energy imaging was investigated by computer simulation and experimental studies. In addition, the accuracy of bone mineral content measurement by this method was also investigated.

UR - http://www.scopus.com/inward/record.url?scp=0026338148&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0026338148&partnerID=8YFLogxK

U2 - 10.1007/BF02347874

DO - 10.1007/BF02347874

M3 - Article

AN - SCOPUS:0026338148

VL - 7

SP - 31

EP - 40

JO - Oral Radiology

JF - Oral Radiology

SN - 0911-6028

IS - 2

ER -