Soft scrubbing off of zona pellucida on disposable microfluidic chip

Yoko Yamanishi, Takehito Mizunuma, Naoki Inomata, Shogo Kudo, Funihito Arai

研究成果: 著書/レポートタイプへの貢献会議での発言

8 引用 (Scopus)

抄録

We succeeded in automation of removal of the zona pellucida of swine oocyte using magnetically driven microtool (MMT) in microfluidic chip. The proposed system can manipulate multiple oocytes at one time with high stability which has an strong advantages over the conventional manual manipulation of removal one by one with pipetting. We proposed the automation of removal of zona pellucida by activating soft polymeric materials in a disposable microfluidic chip to achieve mass production of manipulated embryos as well as accurate and stable manipulations. It can be a breakthrough of a high throughput of accurate and effective oocyte manipulations in the field of cloning and fertility treatment.

元の言語英語
ホスト出版物のタイトルMEMS 2010 - The 23rd IEEE International Conference on Micro Electro Mechanical Systems, Technical Digest
ページ256-259
ページ数4
DOI
出版物ステータス出版済み - 6 1 2010
イベント23rd IEEE International Conference on Micro Electro Mechanical Systems, MEMS 2010 - Hong Kong, 中国
継続期間: 1 24 20101 28 2010

出版物シリーズ

名前Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS)
ISSN(印刷物)1084-6999

その他

その他23rd IEEE International Conference on Micro Electro Mechanical Systems, MEMS 2010
中国
Hong Kong
期間1/24/101/28/10

Fingerprint

gametocytes
washing
Microfluidics
manipulators
chips
automation
Automation
fertility
swine
Cloning
embryos
Throughput
Polymers

All Science Journal Classification (ASJC) codes

  • Electronic, Optical and Magnetic Materials
  • Condensed Matter Physics
  • Mechanical Engineering
  • Electrical and Electronic Engineering

これを引用

Yamanishi, Y., Mizunuma, T., Inomata, N., Kudo, S., & Arai, F. (2010). Soft scrubbing off of zona pellucida on disposable microfluidic chip. : MEMS 2010 - The 23rd IEEE International Conference on Micro Electro Mechanical Systems, Technical Digest (pp. 256-259). [5442516] (Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS)). https://doi.org/10.1109/MEMSYS.2010.5442516

Soft scrubbing off of zona pellucida on disposable microfluidic chip. / Yamanishi, Yoko; Mizunuma, Takehito; Inomata, Naoki; Kudo, Shogo; Arai, Funihito.

MEMS 2010 - The 23rd IEEE International Conference on Micro Electro Mechanical Systems, Technical Digest. 2010. p. 256-259 5442516 (Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS)).

研究成果: 著書/レポートタイプへの貢献会議での発言

Yamanishi, Y, Mizunuma, T, Inomata, N, Kudo, S & Arai, F 2010, Soft scrubbing off of zona pellucida on disposable microfluidic chip. : MEMS 2010 - The 23rd IEEE International Conference on Micro Electro Mechanical Systems, Technical Digest., 5442516, Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS), pp. 256-259, 23rd IEEE International Conference on Micro Electro Mechanical Systems, MEMS 2010, Hong Kong, 中国, 1/24/10. https://doi.org/10.1109/MEMSYS.2010.5442516
Yamanishi Y, Mizunuma T, Inomata N, Kudo S, Arai F. Soft scrubbing off of zona pellucida on disposable microfluidic chip. : MEMS 2010 - The 23rd IEEE International Conference on Micro Electro Mechanical Systems, Technical Digest. 2010. p. 256-259. 5442516. (Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS)). https://doi.org/10.1109/MEMSYS.2010.5442516
Yamanishi, Yoko ; Mizunuma, Takehito ; Inomata, Naoki ; Kudo, Shogo ; Arai, Funihito. / Soft scrubbing off of zona pellucida on disposable microfluidic chip. MEMS 2010 - The 23rd IEEE International Conference on Micro Electro Mechanical Systems, Technical Digest. 2010. pp. 256-259 (Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS)).
@inproceedings{8599f29726544b2aad2fd73914bdd531,
title = "Soft scrubbing off of zona pellucida on disposable microfluidic chip",
abstract = "We succeeded in automation of removal of the zona pellucida of swine oocyte using magnetically driven microtool (MMT) in microfluidic chip. The proposed system can manipulate multiple oocytes at one time with high stability which has an strong advantages over the conventional manual manipulation of removal one by one with pipetting. We proposed the automation of removal of zona pellucida by activating soft polymeric materials in a disposable microfluidic chip to achieve mass production of manipulated embryos as well as accurate and stable manipulations. It can be a breakthrough of a high throughput of accurate and effective oocyte manipulations in the field of cloning and fertility treatment.",
author = "Yoko Yamanishi and Takehito Mizunuma and Naoki Inomata and Shogo Kudo and Funihito Arai",
year = "2010",
month = "6",
day = "1",
doi = "10.1109/MEMSYS.2010.5442516",
language = "English",
isbn = "9781424457649",
series = "Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS)",
pages = "256--259",
booktitle = "MEMS 2010 - The 23rd IEEE International Conference on Micro Electro Mechanical Systems, Technical Digest",

}

TY - GEN

T1 - Soft scrubbing off of zona pellucida on disposable microfluidic chip

AU - Yamanishi, Yoko

AU - Mizunuma, Takehito

AU - Inomata, Naoki

AU - Kudo, Shogo

AU - Arai, Funihito

PY - 2010/6/1

Y1 - 2010/6/1

N2 - We succeeded in automation of removal of the zona pellucida of swine oocyte using magnetically driven microtool (MMT) in microfluidic chip. The proposed system can manipulate multiple oocytes at one time with high stability which has an strong advantages over the conventional manual manipulation of removal one by one with pipetting. We proposed the automation of removal of zona pellucida by activating soft polymeric materials in a disposable microfluidic chip to achieve mass production of manipulated embryos as well as accurate and stable manipulations. It can be a breakthrough of a high throughput of accurate and effective oocyte manipulations in the field of cloning and fertility treatment.

AB - We succeeded in automation of removal of the zona pellucida of swine oocyte using magnetically driven microtool (MMT) in microfluidic chip. The proposed system can manipulate multiple oocytes at one time with high stability which has an strong advantages over the conventional manual manipulation of removal one by one with pipetting. We proposed the automation of removal of zona pellucida by activating soft polymeric materials in a disposable microfluidic chip to achieve mass production of manipulated embryos as well as accurate and stable manipulations. It can be a breakthrough of a high throughput of accurate and effective oocyte manipulations in the field of cloning and fertility treatment.

UR - http://www.scopus.com/inward/record.url?scp=77952768676&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77952768676&partnerID=8YFLogxK

U2 - 10.1109/MEMSYS.2010.5442516

DO - 10.1109/MEMSYS.2010.5442516

M3 - Conference contribution

AN - SCOPUS:77952768676

SN - 9781424457649

T3 - Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS)

SP - 256

EP - 259

BT - MEMS 2010 - The 23rd IEEE International Conference on Micro Electro Mechanical Systems, Technical Digest

ER -