Spatial resolved high-energy particle diagnostic system using time-of-flight neutral particle analyzer in Large Helical Device

Tetsuo Ozaki, Sadayoshi Murakami, Pavel Goncharov, Tsuguhiro Watanabe, Shigeru Sudo, Kazumichi Narihara, Kenji Tanaka, Shin Kubo, Takashi Simozuma, Hiroshi Idei, Yoshihide Oka, Masaki Osakabe, Yasuhiko Takeiri, Katsuyoshi Tsumori, Katsumi Ida, Mamoru Shoji, Hideya Nakanishi, Mamiko Sasao, Osamu Kaneko, Kazuo KawahataYukio Nakamura, Nobuyoshi Ohyabu, Osamu Motojima

研究成果: Contribution to journalConference article査読

6 被引用数 (Scopus)

抄録

The time-of-flight-type neutral particle analyzer, which was able of horizontal continuous scanning during long discharges, was operated in large helical device. Experiments for the comparison between the co- and counter neutral beam injection were performed. It was found that the particle with large pitch angle was lost in the counter injection from the spectrum of the pitch angle distribution of the neutral particles.

本文言語英語
ページ(範囲)1878-1882
ページ数5
ジャーナルReview of Scientific Instruments
74
3 II
DOI
出版ステータス出版済み - 3 2003
外部発表はい
イベントProceedings of the 14th Topical Conference on High - Temperature Plasma Diagnostics - Madison, WI, 米国
継続期間: 7 8 20027 11 2002

All Science Journal Classification (ASJC) codes

  • Instrumentation

フィンガープリント 「Spatial resolved high-energy particle diagnostic system using time-of-flight neutral particle analyzer in Large Helical Device」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。