乾式パネルを用いた大垂壁を有する伝統木造軸組架構の静的加力実験

澁谷 悦敬, 南部 恭広, 大村 早紀, 横部 達也, 杉野 未奈, 林 康裕

研究成果: Contribution to journalArticle査読

抄録

Static loading tests for timber frames with large hanging walls using dry-mud panels were conducted. Following results were obtained. 1) Failure mechanism of the frames is roughly classified into damage of the walls and breakage of the columns. If the columns of the frames were broken, bearing force of the frames is smaller. 2) If the columns of the frames were not broken, restoring force characteristics are varied by specification of the frames. 3) If the side of the columns in which was inserted the <i>Sashigamoi</i> was pulled, the columns are broken at about the half of the flexural strength.
寄稿の翻訳タイトルSTATIC LOADING TESTS FOR TIMBER FRAMES WITH LARGE HANGING WALLS USING DRY-MUD PANELS
本文言語日本語
ページ(範囲)1031-1036
ページ数6
ジャーナルAIJ Journal of Technology and Design
21
49
DOI
出版ステータス出版済み - 2015

フィンガープリント

「乾式パネルを用いた大垂壁を有する伝統木造軸組架構の静的加力実験」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル