Steady-State Characteristics of the Push-Pull DC-to-DC Converter

Masahito Shoyama, Koosuke Harada

研究成果: ジャーナルへの寄稿記事

7 引用 (Scopus)

抄録

Six modes of operation for the push-pull dc-to-dc converter are presented by taking into account the magnetizing current of the transformer. If the inductance of the transformer is decreased, the region where the output voltage is abnormally high is expanded in the load characteristics.

元の言語英語
ページ(範囲)50-56
ページ数7
ジャーナルIEEE Transactions on Aerospace and Electronic Systems
AES-20
発行部数1
DOI
出版物ステータス出版済み - 1984

Fingerprint

Inductance
Electric potential

All Science Journal Classification (ASJC) codes

  • Aerospace Engineering
  • Electrical and Electronic Engineering
  • Computer Networks and Communications

これを引用

Steady-State Characteristics of the Push-Pull DC-to-DC Converter. / Shoyama, Masahito; Harada, Koosuke.

:: IEEE Transactions on Aerospace and Electronic Systems, 巻 AES-20, 番号 1, 1984, p. 50-56.

研究成果: ジャーナルへの寄稿記事

@article{103191c32f5a4db0b9ad5680b9231224,
title = "Steady-State Characteristics of the Push-Pull DC-to-DC Converter",
abstract = "Six modes of operation for the push-pull dc-to-dc converter are presented by taking into account the magnetizing current of the transformer. If the inductance of the transformer is decreased, the region where the output voltage is abnormally high is expanded in the load characteristics.",
author = "Masahito Shoyama and Koosuke Harada",
year = "1984",
doi = "10.1109/TAES.1984.310492",
language = "English",
volume = "AES-20",
pages = "50--56",
journal = "IEEE Transactions on Aerospace and Electronic Systems",
issn = "0018-9251",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "1",

}

TY - JOUR

T1 - Steady-State Characteristics of the Push-Pull DC-to-DC Converter

AU - Shoyama, Masahito

AU - Harada, Koosuke

PY - 1984

Y1 - 1984

N2 - Six modes of operation for the push-pull dc-to-dc converter are presented by taking into account the magnetizing current of the transformer. If the inductance of the transformer is decreased, the region where the output voltage is abnormally high is expanded in the load characteristics.

AB - Six modes of operation for the push-pull dc-to-dc converter are presented by taking into account the magnetizing current of the transformer. If the inductance of the transformer is decreased, the region where the output voltage is abnormally high is expanded in the load characteristics.

UR - http://www.scopus.com/inward/record.url?scp=0021124230&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0021124230&partnerID=8YFLogxK

U2 - 10.1109/TAES.1984.310492

DO - 10.1109/TAES.1984.310492

M3 - Article

VL - AES-20

SP - 50

EP - 56

JO - IEEE Transactions on Aerospace and Electronic Systems

JF - IEEE Transactions on Aerospace and Electronic Systems

SN - 0018-9251

IS - 1

ER -