Sulfur poisoning of SOFCs: Dependence on operational parameters

T. Yoshizumi, C. Uryu, T. Oshima, Y. Shiratori, K. Ito, K. Sasaki

研究成果: Chapter in Book/Report/Conference proceedingConference contribution

9 引用 (Scopus)

抜粋

Sulfur species are major impurities in practical hydrocarbon-based-fuels, chemisorption of which on Ni anode catalysts results in possible performance degradation of SOFC systems. In the present study, degradation of SOFC performance caused by sulfur in prereformed CH 4 has been evaluated under various operational conditions such as current density, fuel utilization, pre-reforming ratio, steam-to-carbon ratio, and operational temperature.

元の言語英語
ホスト出版物のタイトルSolid Oxide Fuel Cells 12, SOFC XII
ページ1717-1725
ページ数9
エディション2 PART 2
DOI
出版物ステータス出版済み - 12 1 2011
イベント12th International Symposium on Solid Oxide Fuel Cells, SOFC-XII - 219th ECS Meeting - Montreal, QC, カナダ
継続期間: 5 1 20115 6 2011

出版物シリーズ

名前ECS Transactions
番号2 PART 2
35
ISSN(印刷物)1938-5862
ISSN(電子版)1938-6737

その他

その他12th International Symposium on Solid Oxide Fuel Cells, SOFC-XII - 219th ECS Meeting
カナダ
Montreal, QC
期間5/1/115/6/11

All Science Journal Classification (ASJC) codes

  • Engineering(all)

フィンガープリント Sulfur poisoning of SOFCs: Dependence on operational parameters' の研究トピックを掘り下げます。これらはともに一意のフィンガープリントを構成します。

  • これを引用

    Yoshizumi, T., Uryu, C., Oshima, T., Shiratori, Y., Ito, K., & Sasaki, K. (2011). Sulfur poisoning of SOFCs: Dependence on operational parameters. : Solid Oxide Fuel Cells 12, SOFC XII (2 PART 2 版, pp. 1717-1725). (ECS Transactions; 巻数 35, 番号 2 PART 2). https://doi.org/10.1149/1.3570159