TY - JOUR
T1 - 13N-ammonia positron emission tomography-derived endocardial strain for the assessment of ischemia using feature-tracking in high-resolution cine imaging
AU - Kawakubo, Masateru
AU - Nagao, Michinobu
AU - Yamamoto, Atsushi
AU - Nakao, Risako
AU - Matsuo, Yuka
AU - Fukushim, Kenji
AU - Watanabe, Eri
AU - Sakai, Akiko
AU - Sasaki, Masayuki
AU - Sakai, Shuji
N1 - Funding Information:
This work was supported by JSPS KAKENHI, Grant Numbers JP20K16729 and JP16K19860.
Publisher Copyright:
© 2021, American Society of Nuclear Cardiology.
PY - 2021
Y1 - 2021
N2 - Background: Assessing endocardial strain using a single 13N-ammonia positron emission tomography (PET) scan would be clinically useful, given the association between ischemia and myocardial deformation. However, no software has been developed for strain analysis using PET. We evaluated the clinical potential of feature tracking-derived strain values measured using PET, based on associations with the myocardial flow reserve (MFR). Methods and Results: This retrospective study included 95 coronary artery disease patients who underwent myocardial 13N-ammonia PET. Semi-automatic measurements were made using a feature-tracking technique during myocardial cine imaging, and values were calculated using a 16-segment model. Adenosine-stressed global circumferential strain (CS) and global longitudinal strain (LS) values were compared with global MFR values. Stressed and resting global strain values were also compared. Global strain values were significantly lower in 39 patients with abnormal MFRs [< 2.0] than in 56 patients with normal MFRs [≥ 2.0]. The global CS values in the stressed state were significantly decreased than the resting state values in patients with abnormal MFRs. Conclusions: This study applied endocardial feature-tracking to 13N-ammonia PET, and the results suggested that blood flow and myocardial motility could be clinically assessed in ischemic patients using a single PET scan.
AB - Background: Assessing endocardial strain using a single 13N-ammonia positron emission tomography (PET) scan would be clinically useful, given the association between ischemia and myocardial deformation. However, no software has been developed for strain analysis using PET. We evaluated the clinical potential of feature tracking-derived strain values measured using PET, based on associations with the myocardial flow reserve (MFR). Methods and Results: This retrospective study included 95 coronary artery disease patients who underwent myocardial 13N-ammonia PET. Semi-automatic measurements were made using a feature-tracking technique during myocardial cine imaging, and values were calculated using a 16-segment model. Adenosine-stressed global circumferential strain (CS) and global longitudinal strain (LS) values were compared with global MFR values. Stressed and resting global strain values were also compared. Global strain values were significantly lower in 39 patients with abnormal MFRs [< 2.0] than in 56 patients with normal MFRs [≥ 2.0]. The global CS values in the stressed state were significantly decreased than the resting state values in patients with abnormal MFRs. Conclusions: This study applied endocardial feature-tracking to 13N-ammonia PET, and the results suggested that blood flow and myocardial motility could be clinically assessed in ischemic patients using a single PET scan.
UR - http://www.scopus.com/inward/record.url?scp=85107524182&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85107524182&partnerID=8YFLogxK
U2 - 10.1007/s12350-021-02677-9
DO - 10.1007/s12350-021-02677-9
M3 - Article
C2 - 34117615
AN - SCOPUS:85107524182
SN - 1071-3581
JO - Journal of Nuclear Cardiology
JF - Journal of Nuclear Cardiology
ER -