Surface wettability and subcooling on nucleate pool boiling heat transfer

Bambang Joko Suroto, Masamichi Kohno, Yasuyuki Takata

研究成果: 著書/レポートタイプへの貢献会議での発言

1 引用 (Scopus)

抄録

The effect of varying surface wettabilities and subcooling on nucleate pool boiling heat transfer at intermediate heat flux has been examined and investigated. The experiments were performed using pure water as the working fluid and subcooling ranging from 0, 5 and 10 K, respectively. The three types of heat transfer block were used that are bare surface/hydrophilic (polished copper), superhydrophilic/TiO2-coated on copper and hydrophobic/PTFE surface. The experimental results will be examined by the existing model. The results show that the heat transfer performance of surfaces with PTFE coating is better at low heat flux. While for an intermediate heat flux, superhydrophilic surface (TiO2) is superior compared to hydrophilic and hydrophobic surfaces. It is observed that the heat transfer performance is decreasing when the sub cooling degree is increased.

元の言語英語
ホスト出版物のタイトル1st International Conference and Exhibition on Powder Technology Indonesia, ICePTi 2017
編集者I Made Joni, Camellia Panatarani
出版者American Institute of Physics Inc.
ISBN(電子版)9780735416192
DOI
出版物ステータス出版済み - 2 9 2018
イベント1st International Conference and Exhibition on Powder Technology Indonesia, ICePTi 2017 - Jatinangor, インドネシア
継続期間: 8 8 20178 9 2017

出版物シリーズ

名前AIP Conference Proceedings
1927
ISSN(印刷物)0094-243X
ISSN(電子版)1551-7616

その他

その他1st International Conference and Exhibition on Powder Technology Indonesia, ICePTi 2017
インドネシア
Jatinangor
期間8/8/178/9/17

Fingerprint

wettability
boiling
heat transfer
heat flux
copper
working fluids
cooling
coatings
water

All Science Journal Classification (ASJC) codes

  • Physics and Astronomy(all)

これを引用

Suroto, B. J., Kohno, M., & Takata, Y. (2018). Surface wettability and subcooling on nucleate pool boiling heat transfer. : I. M. Joni, & C. Panatarani (版), 1st International Conference and Exhibition on Powder Technology Indonesia, ICePTi 2017 [030047] (AIP Conference Proceedings; 巻数 1927). American Institute of Physics Inc.. https://doi.org/10.1063/1.5021240

Surface wettability and subcooling on nucleate pool boiling heat transfer. / Suroto, Bambang Joko; Kohno, Masamichi; Takata, Yasuyuki.

1st International Conference and Exhibition on Powder Technology Indonesia, ICePTi 2017. 版 / I Made Joni; Camellia Panatarani. American Institute of Physics Inc., 2018. 030047 (AIP Conference Proceedings; 巻 1927).

研究成果: 著書/レポートタイプへの貢献会議での発言

Suroto, BJ, Kohno, M & Takata, Y 2018, Surface wettability and subcooling on nucleate pool boiling heat transfer. : IM Joni & C Panatarani (版), 1st International Conference and Exhibition on Powder Technology Indonesia, ICePTi 2017., 030047, AIP Conference Proceedings, 巻. 1927, American Institute of Physics Inc., 1st International Conference and Exhibition on Powder Technology Indonesia, ICePTi 2017, Jatinangor, インドネシア, 8/8/17. https://doi.org/10.1063/1.5021240
Suroto BJ, Kohno M, Takata Y. Surface wettability and subcooling on nucleate pool boiling heat transfer. : Joni IM, Panatarani C, 編集者, 1st International Conference and Exhibition on Powder Technology Indonesia, ICePTi 2017. American Institute of Physics Inc. 2018. 030047. (AIP Conference Proceedings). https://doi.org/10.1063/1.5021240
Suroto, Bambang Joko ; Kohno, Masamichi ; Takata, Yasuyuki. / Surface wettability and subcooling on nucleate pool boiling heat transfer. 1st International Conference and Exhibition on Powder Technology Indonesia, ICePTi 2017. 編集者 / I Made Joni ; Camellia Panatarani. American Institute of Physics Inc., 2018. (AIP Conference Proceedings).
@inproceedings{b0bf62583a5248cc8880c7dba5be256b,
title = "Surface wettability and subcooling on nucleate pool boiling heat transfer",
abstract = "The effect of varying surface wettabilities and subcooling on nucleate pool boiling heat transfer at intermediate heat flux has been examined and investigated. The experiments were performed using pure water as the working fluid and subcooling ranging from 0, 5 and 10 K, respectively. The three types of heat transfer block were used that are bare surface/hydrophilic (polished copper), superhydrophilic/TiO2-coated on copper and hydrophobic/PTFE surface. The experimental results will be examined by the existing model. The results show that the heat transfer performance of surfaces with PTFE coating is better at low heat flux. While for an intermediate heat flux, superhydrophilic surface (TiO2) is superior compared to hydrophilic and hydrophobic surfaces. It is observed that the heat transfer performance is decreasing when the sub cooling degree is increased.",
author = "Suroto, {Bambang Joko} and Masamichi Kohno and Yasuyuki Takata",
year = "2018",
month = "2",
day = "9",
doi = "10.1063/1.5021240",
language = "English",
series = "AIP Conference Proceedings",
publisher = "American Institute of Physics Inc.",
editor = "Joni, {I Made} and Camellia Panatarani",
booktitle = "1st International Conference and Exhibition on Powder Technology Indonesia, ICePTi 2017",

}

TY - GEN

T1 - Surface wettability and subcooling on nucleate pool boiling heat transfer

AU - Suroto, Bambang Joko

AU - Kohno, Masamichi

AU - Takata, Yasuyuki

PY - 2018/2/9

Y1 - 2018/2/9

N2 - The effect of varying surface wettabilities and subcooling on nucleate pool boiling heat transfer at intermediate heat flux has been examined and investigated. The experiments were performed using pure water as the working fluid and subcooling ranging from 0, 5 and 10 K, respectively. The three types of heat transfer block were used that are bare surface/hydrophilic (polished copper), superhydrophilic/TiO2-coated on copper and hydrophobic/PTFE surface. The experimental results will be examined by the existing model. The results show that the heat transfer performance of surfaces with PTFE coating is better at low heat flux. While for an intermediate heat flux, superhydrophilic surface (TiO2) is superior compared to hydrophilic and hydrophobic surfaces. It is observed that the heat transfer performance is decreasing when the sub cooling degree is increased.

AB - The effect of varying surface wettabilities and subcooling on nucleate pool boiling heat transfer at intermediate heat flux has been examined and investigated. The experiments were performed using pure water as the working fluid and subcooling ranging from 0, 5 and 10 K, respectively. The three types of heat transfer block were used that are bare surface/hydrophilic (polished copper), superhydrophilic/TiO2-coated on copper and hydrophobic/PTFE surface. The experimental results will be examined by the existing model. The results show that the heat transfer performance of surfaces with PTFE coating is better at low heat flux. While for an intermediate heat flux, superhydrophilic surface (TiO2) is superior compared to hydrophilic and hydrophobic surfaces. It is observed that the heat transfer performance is decreasing when the sub cooling degree is increased.

UR - http://www.scopus.com/inward/record.url?scp=85042082506&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85042082506&partnerID=8YFLogxK

U2 - 10.1063/1.5021240

DO - 10.1063/1.5021240

M3 - Conference contribution

AN - SCOPUS:85042082506

T3 - AIP Conference Proceedings

BT - 1st International Conference and Exhibition on Powder Technology Indonesia, ICePTi 2017

A2 - Joni, I Made

A2 - Panatarani, Camellia

PB - American Institute of Physics Inc.

ER -