Tail suppression with particle identification technique in stacked NaI(Tl) spectrometer for intermediate energy

H. Murohka, H. Yoshida, O. Iwamoto, Yusuke Uozumi, Akihiro Nohtomi, T. Sakae, M. Matoba, T. Maki, N. Koori

研究成果: 会議への寄与タイプ論文

抄録

A stacked NaI(Tl) spectrometer which consists of two silicon detectors, 4 rectangular NaI(Tl) scintillators (2 inches ×2 inches ×2 inches) and a cylindrical NaI(Tl) scintillator (φ8 cm × 18 cm) has been developed to detect spectrum of charged particles up to about 400MeV. Tests were performed using 300 and 350MeV proton beams from the ring cyclotron at the Research Center for Nuclear Physics (RCNP), Osaka university. The ΔE-E technique was used to identify particles and also events which originated to nuclear reactions in the detector materials. The tail of peak spectrum is suppressed clearly and the peak efficiency is reasonably estimated.

元の言語英語
ページ800-804
ページ数5
出版物ステータス出版済み - 12 1 1995
イベントProceedings of the 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference. Part 1 (of 3) - San Francisco, CA, USA
継続期間: 10 21 199510 28 1995

その他

その他Proceedings of the 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference. Part 1 (of 3)
San Francisco, CA, USA
期間10/21/9510/28/95

Fingerprint

Phosphors
Spectrometers
Nuclear physics
Silicon detectors
Proton beams
Nuclear reactions
Cyclotrons
Charged particles
Detectors

All Science Journal Classification (ASJC) codes

  • Computer Vision and Pattern Recognition
  • Industrial and Manufacturing Engineering

これを引用

Murohka, H., Yoshida, H., Iwamoto, O., Uozumi, Y., Nohtomi, A., Sakae, T., ... Koori, N. (1995). Tail suppression with particle identification technique in stacked NaI(Tl) spectrometer for intermediate energy. 800-804. 論文発表場所 Proceedings of the 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference. Part 1 (of 3), San Francisco, CA, USA, .

Tail suppression with particle identification technique in stacked NaI(Tl) spectrometer for intermediate energy. / Murohka, H.; Yoshida, H.; Iwamoto, O.; Uozumi, Yusuke; Nohtomi, Akihiro; Sakae, T.; Matoba, M.; Maki, T.; Koori, N.

1995. 800-804 論文発表場所 Proceedings of the 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference. Part 1 (of 3), San Francisco, CA, USA, .

研究成果: 会議への寄与タイプ論文

Murohka, H, Yoshida, H, Iwamoto, O, Uozumi, Y, Nohtomi, A, Sakae, T, Matoba, M, Maki, T & Koori, N 1995, 'Tail suppression with particle identification technique in stacked NaI(Tl) spectrometer for intermediate energy' 論文発表場所 Proceedings of the 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference. Part 1 (of 3), San Francisco, CA, USA, 10/21/95 - 10/28/95, pp. 800-804.
Murohka H, Yoshida H, Iwamoto O, Uozumi Y, Nohtomi A, Sakae T その他. Tail suppression with particle identification technique in stacked NaI(Tl) spectrometer for intermediate energy. 1995. 論文発表場所 Proceedings of the 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference. Part 1 (of 3), San Francisco, CA, USA, .
Murohka, H. ; Yoshida, H. ; Iwamoto, O. ; Uozumi, Yusuke ; Nohtomi, Akihiro ; Sakae, T. ; Matoba, M. ; Maki, T. ; Koori, N. / Tail suppression with particle identification technique in stacked NaI(Tl) spectrometer for intermediate energy. 論文発表場所 Proceedings of the 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference. Part 1 (of 3), San Francisco, CA, USA, .5 p.
@conference{2c832caaf26c47e791d50ba7dcf765e7,
title = "Tail suppression with particle identification technique in stacked NaI(Tl) spectrometer for intermediate energy",
abstract = "A stacked NaI(Tl) spectrometer which consists of two silicon detectors, 4 rectangular NaI(Tl) scintillators (2 inches ×2 inches ×2 inches) and a cylindrical NaI(Tl) scintillator (φ8 cm × 18 cm) has been developed to detect spectrum of charged particles up to about 400MeV. Tests were performed using 300 and 350MeV proton beams from the ring cyclotron at the Research Center for Nuclear Physics (RCNP), Osaka university. The ΔE-E technique was used to identify particles and also events which originated to nuclear reactions in the detector materials. The tail of peak spectrum is suppressed clearly and the peak efficiency is reasonably estimated.",
author = "H. Murohka and H. Yoshida and O. Iwamoto and Yusuke Uozumi and Akihiro Nohtomi and T. Sakae and M. Matoba and T. Maki and N. Koori",
year = "1995",
month = "12",
day = "1",
language = "English",
pages = "800--804",
note = "Proceedings of the 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference. Part 1 (of 3) ; Conference date: 21-10-1995 Through 28-10-1995",

}

TY - CONF

T1 - Tail suppression with particle identification technique in stacked NaI(Tl) spectrometer for intermediate energy

AU - Murohka, H.

AU - Yoshida, H.

AU - Iwamoto, O.

AU - Uozumi, Yusuke

AU - Nohtomi, Akihiro

AU - Sakae, T.

AU - Matoba, M.

AU - Maki, T.

AU - Koori, N.

PY - 1995/12/1

Y1 - 1995/12/1

N2 - A stacked NaI(Tl) spectrometer which consists of two silicon detectors, 4 rectangular NaI(Tl) scintillators (2 inches ×2 inches ×2 inches) and a cylindrical NaI(Tl) scintillator (φ8 cm × 18 cm) has been developed to detect spectrum of charged particles up to about 400MeV. Tests were performed using 300 and 350MeV proton beams from the ring cyclotron at the Research Center for Nuclear Physics (RCNP), Osaka university. The ΔE-E technique was used to identify particles and also events which originated to nuclear reactions in the detector materials. The tail of peak spectrum is suppressed clearly and the peak efficiency is reasonably estimated.

AB - A stacked NaI(Tl) spectrometer which consists of two silicon detectors, 4 rectangular NaI(Tl) scintillators (2 inches ×2 inches ×2 inches) and a cylindrical NaI(Tl) scintillator (φ8 cm × 18 cm) has been developed to detect spectrum of charged particles up to about 400MeV. Tests were performed using 300 and 350MeV proton beams from the ring cyclotron at the Research Center for Nuclear Physics (RCNP), Osaka university. The ΔE-E technique was used to identify particles and also events which originated to nuclear reactions in the detector materials. The tail of peak spectrum is suppressed clearly and the peak efficiency is reasonably estimated.

UR - http://www.scopus.com/inward/record.url?scp=0029462120&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0029462120&partnerID=8YFLogxK

M3 - Paper

AN - SCOPUS:0029462120

SP - 800

EP - 804

ER -