We report here a novel chamber-sealing valve that is self-actuated by pressure change during the cyclic temperature changes in PCR processes. Actuation of our valve requirs only a heating device employed for PCR. An UV-curable polymer is used as a device material and it allowed us to realize temperature-driven valve actuation as well as to fabricate a 3D device. The self-actuated microvalve achieves the effective sealing of microchamber for PCR even at 90°C, which is essential to develop highly parallel PCR array device without any complicated actuator circuits.

元の言語英語
ホスト出版物のタイトル15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011
ページ248-250
ページ数3
出版物ステータス出版済み - 12 1 2011
イベント15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011 - Seattle, WA, 米国
継続期間: 10 2 201110 6 2011

出版物シリーズ

名前15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011
1

その他

その他15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011
米国
Seattle, WA
期間10/2/1110/6/11

Fingerprint

Actuators
Heating
Temperature
Networks (circuits)
Polymers

All Science Journal Classification (ASJC) codes

  • Control and Systems Engineering

これを引用

Naito, T., Arayanarakool, R., Kaji, N., Okamoto, Y., Tokeshi, M., Gac, S. L., ... Baba, Y. (2011). Temperature-driven self-actuated microvalve for PCR. : 15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011 (pp. 248-250). (15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011; 巻数 1).

Temperature-driven self-actuated microvalve for PCR. / Naito, Toyohiro; Arayanarakool, Rerngchai; Kaji, Noritada; Okamoto, Yukihiro; Tokeshi, Manabu; Gac, Séverine Le; Van Den Berg, Albert; Baba, Y.

15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011. 2011. p. 248-250 (15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011; 巻 1).

研究成果: 著書/レポートタイプへの貢献会議での発言

Naito, T, Arayanarakool, R, Kaji, N, Okamoto, Y, Tokeshi, M, Gac, SL, Van Den Berg, A & Baba, Y 2011, Temperature-driven self-actuated microvalve for PCR. : 15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011. 15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011, 巻. 1, pp. 248-250, 15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011, Seattle, WA, 米国, 10/2/11.
Naito T, Arayanarakool R, Kaji N, Okamoto Y, Tokeshi M, Gac SL その他. Temperature-driven self-actuated microvalve for PCR. : 15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011. 2011. p. 248-250. (15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011).
Naito, Toyohiro ; Arayanarakool, Rerngchai ; Kaji, Noritada ; Okamoto, Yukihiro ; Tokeshi, Manabu ; Gac, Séverine Le ; Van Den Berg, Albert ; Baba, Y. / Temperature-driven self-actuated microvalve for PCR. 15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011. 2011. pp. 248-250 (15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011).
@inproceedings{57112dcbe41d4ccb966a9cb69c55ae05,
title = "Temperature-driven self-actuated microvalve for PCR",
abstract = "We report here a novel chamber-sealing valve that is self-actuated by pressure change during the cyclic temperature changes in PCR processes. Actuation of our valve requirs only a heating device employed for PCR. An UV-curable polymer is used as a device material and it allowed us to realize temperature-driven valve actuation as well as to fabricate a 3D device. The self-actuated microvalve achieves the effective sealing of microchamber for PCR even at 90°C, which is essential to develop highly parallel PCR array device without any complicated actuator circuits.",
author = "Toyohiro Naito and Rerngchai Arayanarakool and Noritada Kaji and Yukihiro Okamoto and Manabu Tokeshi and Gac, {S{\'e}verine Le} and {Van Den Berg}, Albert and Y. Baba",
year = "2011",
month = "12",
day = "1",
language = "English",
isbn = "9781618395955",
series = "15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011",
pages = "248--250",
booktitle = "15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011",

}

TY - GEN

T1 - Temperature-driven self-actuated microvalve for PCR

AU - Naito, Toyohiro

AU - Arayanarakool, Rerngchai

AU - Kaji, Noritada

AU - Okamoto, Yukihiro

AU - Tokeshi, Manabu

AU - Gac, Séverine Le

AU - Van Den Berg, Albert

AU - Baba, Y.

PY - 2011/12/1

Y1 - 2011/12/1

N2 - We report here a novel chamber-sealing valve that is self-actuated by pressure change during the cyclic temperature changes in PCR processes. Actuation of our valve requirs only a heating device employed for PCR. An UV-curable polymer is used as a device material and it allowed us to realize temperature-driven valve actuation as well as to fabricate a 3D device. The self-actuated microvalve achieves the effective sealing of microchamber for PCR even at 90°C, which is essential to develop highly parallel PCR array device without any complicated actuator circuits.

AB - We report here a novel chamber-sealing valve that is self-actuated by pressure change during the cyclic temperature changes in PCR processes. Actuation of our valve requirs only a heating device employed for PCR. An UV-curable polymer is used as a device material and it allowed us to realize temperature-driven valve actuation as well as to fabricate a 3D device. The self-actuated microvalve achieves the effective sealing of microchamber for PCR even at 90°C, which is essential to develop highly parallel PCR array device without any complicated actuator circuits.

UR - http://www.scopus.com/inward/record.url?scp=84883748674&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84883748674&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:84883748674

SN - 9781618395955

T3 - 15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011

SP - 248

EP - 250

BT - 15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011

ER -