The examination for suitable spec of solid oxide fuel cell co-generation system and the proposal of tank minimization by using bas-tab in collective housing

Daisuke Sumiyoshi, Yuki Okuda, Yasunori Akashi, Akihito Ozaki, Toshiyuki Watanabe

研究成果: ジャーナルへの寄稿記事

4 引用 (Scopus)

抜粋

In this report, the optimized rated power output and the optimized hot water tank capacity of SOFC in accordance with the energy demand of collective housing are clarified. And authors proposed "the bathtub heat storage operation" and clarified its efficiency. The conclusions are as follows. 1. The optimized rated power output related with the total annual demand of electric power and hot water supply. The optimized hot water tank capacity related with the heat-to-power ratio of demand. 2. "The bathtub heat storage operation" was effective in the cases where the hot water tank capacity was less than 30L. It shows that it was possible to make the hot water tank for collective housing smaller without greatly lowering the energy saving efficiency of SOFC.

元の言語英語
ページ(範囲)441-450
ページ数10
ジャーナルJournal of Environmental Engineering (Japan)
80
発行部数711
DOI
出版物ステータス出版済み - 1 1 2015

    フィンガープリント

All Science Journal Classification (ASJC) codes

  • Environmental Engineering

これを引用