The real-time image guidance in otologic surgery

Nozomu Matsumoto, Shizuo Komune, Jaesung Hong, Makoto Hashizume

研究成果: ジャーナルへの寄稿記事

抜粋

We investigated whether the general belief is true that image-guided surgery improves surgical safety but increases the surgical time. We compared intraoperative complications and surgical time in our cochlear implant and acoustic tumor removal surgeries with or without the assistance of image guidance. No comparison was possible in complications which were very rare in both groups. Surgical time was similar in cochlear implant surgeries, which is an established surgery with little variances, with no increase in surgical time was noted in image-guided group. On the other hand, in acoustic tumor removal cases which is more difficult and require more experience, the surgical time was much longer in the image-guided group. It was suggested that surgical time elongation in image-guided surgery depends on the proficiency of the surgeon to the specific surgery, rather than on the use of image-guided surgery itself.

元の言語英語
ページ(範囲)350-353
ページ数4
ジャーナルOto-Rhino-Laryngology Tokyo
52
発行部数5
出版物ステータス出版済み - 10 1 2009

    フィンガープリント

All Science Journal Classification (ASJC) codes

  • Otorhinolaryngology

これを引用

Matsumoto, N., Komune, S., Hong, J., & Hashizume, M. (2009). The real-time image guidance in otologic surgery. Oto-Rhino-Laryngology Tokyo, 52(5), 350-353.