The X-ray microscopy project at Saga SLS

M. Yasumoto, E. Ishiguro, K. Takemoto, T. Tomimasu, H. Kihara, N. Kamijo, T. Tsurushima, Atsushi Takahara, Kazuhiro Hara, Y. Chikaura

研究成果: ジャーナルへの寄稿Conference article

2 引用 (Scopus)

抜粋

A new high resolution X-ray microscopy project has been proposed at Saga synchrotron light source, which is a third generation synchrotron light facility in Japan. Two microscopy beamlines are planned for this project. One is a scanning microscope in the water window region, and the other is a full-field imaging microscope in the multi-keV X-ray energy region. To demonstrate the feasibility of the project, the optical layout of the scanning microscope was designed. The beamline mainly consists of a 3.5 cm periodical undulator, a varied line-spacing plane grating monochorometer (600 lines/mm) and an end-station including a zone plate. Thus, the calculated X-ray properties focused on the sample position are as follows: the spot size is ∼70 nm, the monochromaticity is ∼2000, and the photon flux is 109 ∼ 1010 photons/sec.

元の言語英語
ページ(範囲)63-66
ページ数4
ジャーナルJournal De Physique. IV : JP
104
DOI
出版物ステータス出版済み - 1 1 2003
イベント7th International Conference on X-Ray Microscopy - Grenoble, フランス
継続期間: 7 28 20028 2 2002

    フィンガープリント

All Science Journal Classification (ASJC) codes

  • Physics and Astronomy(all)

これを引用

Yasumoto, M., Ishiguro, E., Takemoto, K., Tomimasu, T., Kihara, H., Kamijo, N., ... Chikaura, Y. (2003). The X-ray microscopy project at Saga SLS. Journal De Physique. IV : JP, 104, 63-66. https://doi.org/10.1051/jp4:200300030