Thermal hydraulic characteristics of turbulent single-phase flow in an enhanced tube using louvered strip insert with various slant angles

Indri Yaningsih, Agung Tri Wijayanta, Takahiko Miyazaki, Shigeru Koyama

研究成果: ジャーナルへの寄稿記事

4 引用 (Scopus)

抄録

Effect of slant angle (α) of louvered strip insert on single-phase forced convection heat transfer and friction factor of internal flow was investigated experimentally. The parameter of slant angles (α) 15° 20° and 25° was examined at the Reynolds number (Re) of 5300–17,500. The plain tube was also performed for comparison. The results show that the louvered strip insert provided the increases in heat transfer and friction factor up to 77.02% and 3.35 times above the plain tube. The results also indicate that heat transfer and friction factor increased with increasing slant angle. The highest slant angle yielded the highest thermal performance factor in the value of 1.12. Empirical correlations were also developed for Nusselt number and friction factor based on experimental data.

元の言語英語
ページ(範囲)355-362
ページ数8
ジャーナルInternational Journal of Thermal Sciences
134
DOI
出版物ステータス出版済み - 12 1 2018

Fingerprint

single-phase flow
inserts
friction factor
hydraulics
strip
Hydraulics
Friction
slopes
tubes
Heat transfer
heat transfer
plains
Forced convection
Nusselt number
internal flow
forced convection
Reynolds number
Hot Temperature

All Science Journal Classification (ASJC) codes

  • Condensed Matter Physics
  • Engineering(all)

これを引用

Thermal hydraulic characteristics of turbulent single-phase flow in an enhanced tube using louvered strip insert with various slant angles. / Yaningsih, Indri; Wijayanta, Agung Tri; Miyazaki, Takahiko; Koyama, Shigeru.

:: International Journal of Thermal Sciences, 巻 134, 01.12.2018, p. 355-362.

研究成果: ジャーナルへの寄稿記事

@article{61f26a990c554bff9e7f1b136620b264,
title = "Thermal hydraulic characteristics of turbulent single-phase flow in an enhanced tube using louvered strip insert with various slant angles",
abstract = "Effect of slant angle (α) of louvered strip insert on single-phase forced convection heat transfer and friction factor of internal flow was investigated experimentally. The parameter of slant angles (α) 15° 20° and 25° was examined at the Reynolds number (Re) of 5300–17,500. The plain tube was also performed for comparison. The results show that the louvered strip insert provided the increases in heat transfer and friction factor up to 77.02{\%} and 3.35 times above the plain tube. The results also indicate that heat transfer and friction factor increased with increasing slant angle. The highest slant angle yielded the highest thermal performance factor in the value of 1.12. Empirical correlations were also developed for Nusselt number and friction factor based on experimental data.",
author = "Indri Yaningsih and Wijayanta, {Agung Tri} and Takahiko Miyazaki and Shigeru Koyama",
year = "2018",
month = "12",
day = "1",
doi = "10.1016/j.ijthermalsci.2018.08.025",
language = "English",
volume = "134",
pages = "355--362",
journal = "International Journal of Thermal Sciences",
issn = "1290-0729",
publisher = "Elsevier Masson SAS",

}

TY - JOUR

T1 - Thermal hydraulic characteristics of turbulent single-phase flow in an enhanced tube using louvered strip insert with various slant angles

AU - Yaningsih, Indri

AU - Wijayanta, Agung Tri

AU - Miyazaki, Takahiko

AU - Koyama, Shigeru

PY - 2018/12/1

Y1 - 2018/12/1

N2 - Effect of slant angle (α) of louvered strip insert on single-phase forced convection heat transfer and friction factor of internal flow was investigated experimentally. The parameter of slant angles (α) 15° 20° and 25° was examined at the Reynolds number (Re) of 5300–17,500. The plain tube was also performed for comparison. The results show that the louvered strip insert provided the increases in heat transfer and friction factor up to 77.02% and 3.35 times above the plain tube. The results also indicate that heat transfer and friction factor increased with increasing slant angle. The highest slant angle yielded the highest thermal performance factor in the value of 1.12. Empirical correlations were also developed for Nusselt number and friction factor based on experimental data.

AB - Effect of slant angle (α) of louvered strip insert on single-phase forced convection heat transfer and friction factor of internal flow was investigated experimentally. The parameter of slant angles (α) 15° 20° and 25° was examined at the Reynolds number (Re) of 5300–17,500. The plain tube was also performed for comparison. The results show that the louvered strip insert provided the increases in heat transfer and friction factor up to 77.02% and 3.35 times above the plain tube. The results also indicate that heat transfer and friction factor increased with increasing slant angle. The highest slant angle yielded the highest thermal performance factor in the value of 1.12. Empirical correlations were also developed for Nusselt number and friction factor based on experimental data.

UR - http://www.scopus.com/inward/record.url?scp=85051753294&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85051753294&partnerID=8YFLogxK

U2 - 10.1016/j.ijthermalsci.2018.08.025

DO - 10.1016/j.ijthermalsci.2018.08.025

M3 - Article

AN - SCOPUS:85051753294

VL - 134

SP - 355

EP - 362

JO - International Journal of Thermal Sciences