Three-dimensional magnetic nanoparticle imaging using small field gradient and multiple pickup coils

Teruyoshi Sasayama, Yuya Tsujita, Manabu Morishita, Masahiro Muta, Takashi Yoshida, Keiji Enpuku

研究成果: Contribution to journalArticle査読

13 被引用数 (Scopus)

抄録

We propose a magnetic particle imaging (MPI) method based on third harmonic signal detection using a small field gradient and multiple pickup coils. First, we developed a system using two pickup coils and performed three-dimensional detection of two magnetic nanoparticle (MNP) samples, which were spaced 15 mm apart. In the experiments, an excitation field strength of 1.6 mT was used at an operating frequency of 3 kHz. A DC gradient field with a typical value of 0.2 T/m was also used to produce the so-called field-free line. A third harmonic signal generated by the MNP samples was detected using the two pickup coils, and the samples were then mechanically scanned to obtain field maps. The field maps were subsequently analyzed using the nonnegative least squares method to obtain three-dimensional position information for the MNP samples. The results show that the positions of the two MNP samples were estimated with good accuracy, despite the small field gradient used. Further improvement in MPI performance will be achieved by increasing the number of pickup coils used.

本文言語英語
ページ(範囲)144-150
ページ数7
ジャーナルJournal of Magnetism and Magnetic Materials
427
DOI
出版ステータス出版済み - 4 1 2017

All Science Journal Classification (ASJC) codes

  • 電子材料、光学材料、および磁性材料
  • 凝縮系物理学

フィンガープリント

「Three-dimensional magnetic nanoparticle imaging using small field gradient and multiple pickup coils」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル