Tritium monitoring using magnetically-levitated-electrode ionization chambers

Hirorumi Ichiki, Toshirou Kawaguchi, Kenji Ishibashi, Nobuo Ikeda, Satoshi Fukada, Gen Ichirou Wakabayashi, Yoshiya Kawabata

研究成果: ジャーナルへの寄稿記事

抄録

We developed a high precision ionization chamber MALIC. It is an integral type ionization chamber which has a magnetically levitated electrode without being supported by insulation materials. Furthermore, the electric potential of that electrode can be read without physical contact, so that the contact noise does not occur. With MALIC, we attempted to measure the radiation dose from tritium vapor of a room air in an accelerator facility.

元の言語英語
ページ(範囲)994-997
ページ数4
ジャーナルFusion Science and Technology
60
発行部数3
DOI
出版物ステータス出版済み - 1 1 2011

Fingerprint

Ionization chambers
Tritium
ionization chambers
tritium
Electrodes
electrodes
Monitoring
insulation
Dosimetry
Particle accelerators
rooms
Insulation
accelerators
Vapors
vapors
dosage
air
Electric potential
electric potential
radiation

All Science Journal Classification (ASJC) codes

  • Civil and Structural Engineering
  • Nuclear and High Energy Physics
  • Nuclear Energy and Engineering
  • Materials Science(all)
  • Mechanical Engineering

これを引用

Ichiki, H., Kawaguchi, T., Ishibashi, K., Ikeda, N., Fukada, S., Wakabayashi, G. I., & Kawabata, Y. (2011). Tritium monitoring using magnetically-levitated-electrode ionization chambers. Fusion Science and Technology, 60(3), 994-997. https://doi.org/10.13182/FST11-A12583

Tritium monitoring using magnetically-levitated-electrode ionization chambers. / Ichiki, Hirorumi; Kawaguchi, Toshirou; Ishibashi, Kenji; Ikeda, Nobuo; Fukada, Satoshi; Wakabayashi, Gen Ichirou; Kawabata, Yoshiya.

:: Fusion Science and Technology, 巻 60, 番号 3, 01.01.2011, p. 994-997.

研究成果: ジャーナルへの寄稿記事

Ichiki, H, Kawaguchi, T, Ishibashi, K, Ikeda, N, Fukada, S, Wakabayashi, GI & Kawabata, Y 2011, 'Tritium monitoring using magnetically-levitated-electrode ionization chambers', Fusion Science and Technology, 巻. 60, 番号 3, pp. 994-997. https://doi.org/10.13182/FST11-A12583
Ichiki, Hirorumi ; Kawaguchi, Toshirou ; Ishibashi, Kenji ; Ikeda, Nobuo ; Fukada, Satoshi ; Wakabayashi, Gen Ichirou ; Kawabata, Yoshiya. / Tritium monitoring using magnetically-levitated-electrode ionization chambers. :: Fusion Science and Technology. 2011 ; 巻 60, 番号 3. pp. 994-997.
@article{e9e664a9d91245a195523c6023ca864c,
title = "Tritium monitoring using magnetically-levitated-electrode ionization chambers",
abstract = "We developed a high precision ionization chamber MALIC. It is an integral type ionization chamber which has a magnetically levitated electrode without being supported by insulation materials. Furthermore, the electric potential of that electrode can be read without physical contact, so that the contact noise does not occur. With MALIC, we attempted to measure the radiation dose from tritium vapor of a room air in an accelerator facility.",
author = "Hirorumi Ichiki and Toshirou Kawaguchi and Kenji Ishibashi and Nobuo Ikeda and Satoshi Fukada and Wakabayashi, {Gen Ichirou} and Yoshiya Kawabata",
year = "2011",
month = "1",
day = "1",
doi = "10.13182/FST11-A12583",
language = "English",
volume = "60",
pages = "994--997",
journal = "Fusion Science and Technology",
issn = "1536-1055",
publisher = "American Nuclear Society",
number = "3",

}

TY - JOUR

T1 - Tritium monitoring using magnetically-levitated-electrode ionization chambers

AU - Ichiki, Hirorumi

AU - Kawaguchi, Toshirou

AU - Ishibashi, Kenji

AU - Ikeda, Nobuo

AU - Fukada, Satoshi

AU - Wakabayashi, Gen Ichirou

AU - Kawabata, Yoshiya

PY - 2011/1/1

Y1 - 2011/1/1

N2 - We developed a high precision ionization chamber MALIC. It is an integral type ionization chamber which has a magnetically levitated electrode without being supported by insulation materials. Furthermore, the electric potential of that electrode can be read without physical contact, so that the contact noise does not occur. With MALIC, we attempted to measure the radiation dose from tritium vapor of a room air in an accelerator facility.

AB - We developed a high precision ionization chamber MALIC. It is an integral type ionization chamber which has a magnetically levitated electrode without being supported by insulation materials. Furthermore, the electric potential of that electrode can be read without physical contact, so that the contact noise does not occur. With MALIC, we attempted to measure the radiation dose from tritium vapor of a room air in an accelerator facility.

UR - http://www.scopus.com/inward/record.url?scp=82055171610&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=82055171610&partnerID=8YFLogxK

U2 - 10.13182/FST11-A12583

DO - 10.13182/FST11-A12583

M3 - Article

VL - 60

SP - 994

EP - 997

JO - Fusion Science and Technology

JF - Fusion Science and Technology

SN - 1536-1055

IS - 3

ER -