Ultra-long pulse operation using lower hybrid waves on the superconducting high field tokamak triam-im

S. Moriyama, Y. Nakamura, A. Nagao, E. Jotaki, K. Nakamura, N. Hiraki, S. Itoh

研究成果: ジャーナルへの寄稿学術誌査読

11 被引用数 (Scopus)

抄録

Ultra-long pulse operation (> 3 min) was achieved on the superconducting high field tokamak TRIAM-1M. In this operation, the plasma current was maintained with a relatively peaked current distribution by the 2.45 GHz radiofrequency power (PRF < 35 kW) alone. A stationary plasma with a driven current of up to 35 kA and a line averaged electron density of up to 3 x 1012 cm"3 was produced by precise plasma position and gas feed control. The extremely long discharge showed the interesting characteristics that the high temperatures of about 1 keV for the electrons and about 0.5 keV for the ions were kept almost constant during steady state current drive and that there was no impurity accumulation which could have a fatally adverse effect on steady state tokamak operation.

本文言語英語
ページ(範囲)47-56
ページ数10
ジャーナルNuclear Fusion
30
1
DOI
出版ステータス出版済み - 1月 1990