Unburned carbon measurement in fly ash using laser-induced breakdown spectroscopy with short nanosecond pulse width laser

Renwei Liu, Yoshihiro Deguchi, Weigang Nan, Ruomu Hu, Zhenzhen Wang, Yuki Fujita, Seiya Tanaka, Kazuki Tainaka, Kenji Tanno, Hiroaki Watanabe, Jiping Liu, Junjie Yan

研究成果: ジャーナルへの寄稿記事

1 引用 (Scopus)

抜粋

The unburned carbon in fly ash is one of the important factors for the boiler combustion condition. Controlling the unburned carbon in fly ash is beneficial for fly ash recycle and to improve the combustion efficiency of the coal. Laser-induced breakdown spectroscopy (LIBS) technology has been applied to measure the fly ash contents due to its merits of non-contact, fast response, high sensitivity, and real-time measurement. In this study, experimental measurements have been adopted for fly ash flows with the surrounding gases of N 2 and CO 2 , while the CO 2 concentration varified to evaluate the CO 2 effect on the unburned carbon signal from fly ash powder. Two kinds of pulse width lasers, 6 ns and 1 ns, were separately adopted to compare the influence of laser pulse width. Results showed that compared with that using 6 ns pulse width laser, plasma temperature was lower and had less dependence on delay time when using 1 ns pulse width laser, and spectra had more stable background. By using 1 ns pulse width laser, the emission signal from surrounding CO 2 also decreased because of the less surrounding gas breakdown. The solid powder breakdown signals also became more stable when using 1 ns pulse width laser. It is demonstrated that 1 ns pulse width laser has the merits for fly ash flow measurement using LIBS.

元の言語英語
ページ(範囲)1210-1218
ページ数9
ジャーナルAdvanced Powder Technology
30
発行部数6
DOI
出版物ステータス出版済み - 6 2019

    フィンガープリント

All Science Journal Classification (ASJC) codes

  • Chemical Engineering(all)
  • Mechanics of Materials

これを引用