T1 - Use of a long distally fixed intramedullary stem to treat a periprosthetic femoral fracture following total hip arthroplasty using a thrust plate hip prosthesis
T2 - A case report
AU - Hatanaka, Hiroyuki
AU - Motomura, Goro
AU - Ikemura, Satoshi
AU - Sonoda, Kazuhiko
AU - Kubo, Yusuke
AU - Utsunomiya, Takeshi
AU - Yamamoto, Takuaki
AU - Nakashima, Yasuharu
N1 - Funding Information:
This work was supported in part by a Grant-in-Aid for Scientific Research [grant numbers 16K10906 and 16H07057] from the Japan Society for the Promotion of Science.
Publisher Copyright:
© 2017 The Author(s)
PY - 2017
Y1 - 2017
N2 - Introduction The thrust plate hip prosthesis (TPP; Zimmer, Winterthur, Switzerland) is a hip prosthesis that is no longer in production. Few reports have focused on periprosthetic fractures following total hip arthroplasty (THA) with the use of a TPP. Presentation of case We report a 57-year-old woman with a periprosthetic femoral fracture 13 years after THA with the use of a TPP. A plain radiograph showed a displaced subtrochanteric fracture of the right femur just below the distal tip of the lateral plate without implant loosening. She underwent revision surgery with a long distally fixed intramedullary stem in conjunction with a plate and cable system. Three months after surgery, bone union was confirmed using radiography and the patient was clinically asymptomatic. Discussion We encountered three major problems while planning surgical treatment, these being, discontinuation of the TPP system, loss of proximal femoral cancellous bone, and difficulties with the type of subtrochanteric fracture. After considering these problems, we planned revision surgery using a long distally fixed intramedullary stem in conjunction with a plate and cable system. Conclusion This case shows that sufficient implant preparation based on precise preoperative planning is necessary to obtain good clinical results for the surgical treatment of periprosthetic femoral fractures following THA with the use of a TPP.
AB - Introduction The thrust plate hip prosthesis (TPP; Zimmer, Winterthur, Switzerland) is a hip prosthesis that is no longer in production. Few reports have focused on periprosthetic fractures following total hip arthroplasty (THA) with the use of a TPP. Presentation of case We report a 57-year-old woman with a periprosthetic femoral fracture 13 years after THA with the use of a TPP. A plain radiograph showed a displaced subtrochanteric fracture of the right femur just below the distal tip of the lateral plate without implant loosening. She underwent revision surgery with a long distally fixed intramedullary stem in conjunction with a plate and cable system. Three months after surgery, bone union was confirmed using radiography and the patient was clinically asymptomatic. Discussion We encountered three major problems while planning surgical treatment, these being, discontinuation of the TPP system, loss of proximal femoral cancellous bone, and difficulties with the type of subtrochanteric fracture. After considering these problems, we planned revision surgery using a long distally fixed intramedullary stem in conjunction with a plate and cable system. Conclusion This case shows that sufficient implant preparation based on precise preoperative planning is necessary to obtain good clinical results for the surgical treatment of periprosthetic femoral fractures following THA with the use of a TPP.
UR - http://www.scopus.com/inward/record.url?scp=85020856432&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85020856432&partnerID=8YFLogxK
U2 - 10.1016/j.ijscr.2017.06.010
DO - 10.1016/j.ijscr.2017.06.010
M3 - Article
AN - SCOPUS:85020856432
VL - 37
SP - 65
EP - 68