This study describes a new approach to provide detailed quantification of the impact of surgical intervention on bilateral nasal airflow using voxel-based simulation. Computed tomography and magnetic resonance imaging scans were used to reconstruct 3D realistic models of both the pre- and post-operative nasal airways. Voxel-based simulation of quiet restful inspiratory flow was then performed using meshes of varying refinement to determine the level of mesh refinement required to adequately resolve the flow and heat transfer. For meshes with voxel pitches of 0.10 mm, the voxel model successfully simulated the overall pressure drop and airflow temperatures.
元の言語Japanese
ページ(範囲)33-41
ページ数9
ジャーナルBME = Bio medical engineering / henshu, Nihon ME Gakkai
52
発行部数1
DOI
出版物ステータス出版済み - 2014

Fingerprint

Magnetic resonance
Air
Pressure drop
Tomography
Heat transfer
Imaging techniques
Temperature

これを引用

医療画像に基づく鼻腔内熱流動のボクセルシミュレーション. / 水谷崇志; 磯部光基; 田中学; 世良俊博; 小野謙二.

:: BME = Bio medical engineering / henshu, Nihon ME Gakkai, 巻 52, 番号 1, 2014, p. 33-41.

研究成果: ジャーナルへの寄稿記事

@article{5a9454aa29ac4b62aa50c575759a7efd,
title = "医療画像に基づく鼻腔内熱流動のボクセルシミュレーション",
abstract = "This study describes a new approach to provide detailed quantification of the impact of surgical intervention on bilateral nasal airflow using voxel-based simulation. Computed tomography and magnetic resonance imaging scans were used to reconstruct 3D realistic models of both the pre- and post-operative nasal airways. Voxel-based simulation of quiet restful inspiratory flow was then performed using meshes of varying refinement to determine the level of mesh refinement required to adequately resolve the flow and heat transfer. For meshes with voxel pitches of 0.10 mm, the voxel model successfully simulated the overall pressure drop and airflow temperatures.",
author = "崇志 水谷 and 光基 磯部 and 学 田中 and 俊博 世良 and 謙二 小野",
year = "2014",
doi = "10.11239/jsmbe.52.33",
language = "Japanese",
volume = "52",
pages = "33--41",
journal = "BME = Bio medical engineering / henshu, Nihon ME Gakkai",
issn = "1347-443X",
publisher = "Japanese Society for Medical and Biological Engineering",
number = "1",

}

TY - JOUR

T1 - 医療画像に基づく鼻腔内熱流動のボクセルシミュレーション

AU - 水谷, 崇志

AU - 磯部, 光基

AU - 田中, 学

AU - 世良, 俊博

AU - 小野, 謙二

PY - 2014

Y1 - 2014

N2 - This study describes a new approach to provide detailed quantification of the impact of surgical intervention on bilateral nasal airflow using voxel-based simulation. Computed tomography and magnetic resonance imaging scans were used to reconstruct 3D realistic models of both the pre- and post-operative nasal airways. Voxel-based simulation of quiet restful inspiratory flow was then performed using meshes of varying refinement to determine the level of mesh refinement required to adequately resolve the flow and heat transfer. For meshes with voxel pitches of 0.10 mm, the voxel model successfully simulated the overall pressure drop and airflow temperatures.

AB - This study describes a new approach to provide detailed quantification of the impact of surgical intervention on bilateral nasal airflow using voxel-based simulation. Computed tomography and magnetic resonance imaging scans were used to reconstruct 3D realistic models of both the pre- and post-operative nasal airways. Voxel-based simulation of quiet restful inspiratory flow was then performed using meshes of varying refinement to determine the level of mesh refinement required to adequately resolve the flow and heat transfer. For meshes with voxel pitches of 0.10 mm, the voxel model successfully simulated the overall pressure drop and airflow temperatures.

U2 - 10.11239/jsmbe.52.33

DO - 10.11239/jsmbe.52.33

M3 - 記事

VL - 52

SP - 33

EP - 41

JO - BME = Bio medical engineering / henshu, Nihon ME Gakkai

JF - BME = Bio medical engineering / henshu, Nihon ME Gakkai

SN - 1347-443X

IS - 1

ER -